PSC Scanners Specifiche Pagina 418

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 440
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 417
F-2 Magellan
®
8100/8200 Scanner
PSC Handheld Data Format Requirements
The following sections describe label transmission formats that are typi-
cally observed in factory configurations of PSC handheld scanners.
RSS-14
• Prefix must be ASCII characters ‘R4’
• Check character must be included in label
• Application identifier “01” must follow the prefix and preceed the
base label
• Label length excluding prefix characters must be 16 characters.
• Example: ‘R40101044123456789’
RSS Expanded
• Prefix must be ASCII characters ‘R4’
Check character must be included in label
UPC-A
• Number system must be included in label data.
• Check digit must be included in label data and is assumed to be
correct.
• Prefix must be an ASCII character 'A' - total length including
prefix must be 13.
• Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
• Number system must be included in label data.
• Check digit must be included in label data and is assumed to be
correct.
• Supplemental data is appended to base label.
• Prefix must be an ASCII character 'A' - total length including
prefix must be 15.
• Example: 'A06099201118712'.
Vedere la pagina 417
1 2 ... 413 414 415 416 417 418 419 420 421 422 423 ... 439 440

Commenti su questo manuale

Nessun commento